Expert panel backs preventive closure after larger duodenal, right colon resections

Share

An international panel of 65 gastroenterology experts agreed on 22 recommendations for closing defects in the gastrointestinal tract during endoscopic procedures, including preventive closure after removal of larger polyps in the duodenum and right colon. The recommendations emphasize choosing closure techniques based on the size, location, and characteristics of the defect rather than using the same approach for every patient.

The consensus statement, published in Techniques and Innovations in Gastrointestinal Endoscopy, offers practical guidance on the use of endoscopic closure devices.

Led by Maham Hayat, MD, and Dennis Yang, MD, of the Center for Interventional Endoscopy at AdventHealth in Orlando, Florida, the researchers used a modified Delphi process to address differences in clinical practice resulting from the growing number of closure devices and limited high-quality evidence comparing them.

Maham Hayat, MD

“We hope these recommendations provide a practical guiding framework in the area of endoscopic closure, where practice remains highly variable,” Dr. Hayat and Dr. Yang told GI & Hepatology News. “With the growing number of closure devices available, endoscopists have relatively limited comparative evidence to guide when and how these are best utilized.”

The steering committee developed 26 statements covering four areas: general approaches to closure, techniques for using specific devices, preventive closure after endoscopic resection, and management of perforations.

Of the 68 experts invited to participate, 65 completed both rounds of voting between April and October 2025. The panel included 58 interventional endoscopists and seven general gastroenterologists. Most worked at academic medical centers, and more than half had more than a decade of clinical experience.

To reach consensus, a statement needed agreement from at least 80% of the experts and an average score of at least four on a five-point scale. Twenty statements met these requirements in the first round, and two more reached consensus after revisions.

Individualized closure strategies

All panelists agreed that device selection should account for available equipment and the endoscopist’s experience. Nearly all, 98%, agreed that some defects may require more than one closure technique.

For conventional through-the-scope clips, the experts suggested a zipper-like technique for defects wider than 20 mm. The first clip is placed at one edge of the defect, followed by additional clips that gradually bring the tissue edges together. This approach received 92% agreement, though the authors cautioned it is not the preferred or only strategy for every large defect.

The panel also suggested applying firm pressure to the defect and reducing air or gas in the lumen before closing each clip to help bring deeper tissue layers together. This approach received 91% agreement.

For tissue apposition clips, experts cautioned that closing defects wider than 20 mm could leave a gap beneath the surface even when the tissue edges appear closed. The panel advised using additional clips or other closure techniques to close the defect completely.

For over-the-scope clips, all panelists agreed that endoscopists should know the available clip types, and 97% agreed the clip should be positioned perpendicular to the target when possible. When there is a risk of accidentally capturing surrounding structures, the experts favored using graspers or forceps rather than suction to pull tissue into the clip. This approach received 92% agreement.

Endoscopic suturing may be particularly suitable for closing irregularly shaped defects, according to 83% of panelists. The panel also considered simulation-based training, dedicated courses, or proctorship desirable ways to learn over-the-scope suturing, with 97% agreement.

Prophylactic closure of a post-endoscopic mucosal resection mucosal defect in the cecum using through-the-scope clips. First clip is placed at one corner of the defect (A) to “tent” and create a stable anchor point (B). Additional clips are placed in a sequential manner along the defect, each one helping approximate the tissue edges closer for the next clip (C). Complete mucosal closure (D). Figure courtesy of Techniques and Innovations in Gastrointestinal Endoscopy.

When preventive closure is recommended

The panel recommended preventive closure after removal of duodenal polyps measuring at least 15 mm when technically feasible, with 91% agreement. The authors noted that the 15-mm cutoff was arbitrarily determined, based on studies linking bleeding risk to lesion size. For nonpedunculated polyps measuring at least 20 mm in the right colon, 89% supported considering closure to reduce the risk of delayed bleeding.

These recommendations apply regardless of whether endoscopic mucosal resection or endoscopic submucosal dissection was performed. For defects larger than 40 mm, 83% agreed that specialized tissue apposition clips or through-the-scope suturing may be considered, either alone or combined with other closure techniques.

However, the panel did not reach consensus on preventive closure of stomach defects larger than 20 mm, which drew 62% agreement. The authors noted that high-quality evidence for gastric closure remains limited; one observational study of 135 patients found similar delayed bleeding rates with and without closure (6.7% vs. 6.5%).

Managing perforations

For perforations wider than 10 mm, 92% of experts supported using tissue apposition clips to bring the edges together. The same percentage favored over-the-scope suturing for defects larger than 20 mm that extend through the full thickness of the gastrointestinal wall, when technically feasible.

The panel cautioned that shallow helical tack suturing systems may not penetrate deeply enough to provide lasting closure of full-thickness perforations and recommended considering them when other closure methods were unlikely to succeed.

The panel did not reach consensus on whether over-the-scope clips should be preferred for perforations smaller than 15 mm, which drew 65% agreement. The authors wrote that this likely reflects how much perforations vary in size, location, and timing of recognition, and that management should remain individualized.

For chronic gastrointestinal fistulas, 85% favored over-the-scope clips or suturing, citing a higher likelihood of achieving full-thickness tissue apposition. The panel acknowledged, however, that overall clinical success is low and recurrence risk is high.

Perforation after endoscopic mucosal resection of a serrated adenoma located at the appendix (A). Use of a tissue apposition clip to ensure adequate apposition of the underlying submucosa and muscularis propria (B) which facilitated subsequent approximation using through-the-scope clips (C). Resected specimen showing “target sign” consistent with resection of the muscularis propria (D). Figure courtesy of Techniques and Innovations in Gastrointestinal Endoscopy.

Clinical implications and limitations

The authors wrote that the statements are intended to support clinical decision-making on endoscopic closure in the absence of robust comparative data.

The authors emphasized that the recommendations are based on expert opinion rather than formal evidence-based guidelines. Other limitations include possible bias in how the statements were revised and ongoing advances in closure technology.

Further research is needed to determine whether following these recommendations improves patient outcomes, the authors wrote.

Drs. Othman, Draganov, and Yang and numerous consortium members reported consulting, advisory, research, or financial relationships with medical device and pharmaceutical companies, including Boston Scientific, Olympus, Medtronic, and Cook Medical. Other authors reported no conflicts of interest.

Dennis Yang, MD

Expert insight

Dr. Hayat and Dr. Yang offered their perspective on the recommendations.

How do you expect these recommendations to change endoscopic closure practices?

Dr. Hayat and Dr. Yang: The consensus document provides guidance for specific clinical scenarios and techniques. For example, the panel supported prophylactic closure of large post-resection mucosal defects in higher-risk locations, particularly lesions 20 mm or larger in the right colon and 15 mm or larger in the duodenum. Beyond indications for closure, the paper also provides practical tips and device-specific recommendations for optimizing the use of through-the-scope clips, tissue apposition clips, over-the-scope clips, and endoscopic suturing. We also included figures and video demonstrations to illustrate several of these techniques and provide practical examples of their application. We hope these recommendations can provide endoscopists with expert guidance and a clearer framework for approaching endoscopic closure with these devices.

What factors should physicians consider when choosing among closure devices?

Dr. Hayat and Dr. Yang: One of the key takeaways is that there is no single closure device that is optimal for every defect. Device selection should begin with the assessment of the defect itself, including its size, depth, location, tissue quality and mobility, and whether the goal is prophylactic mucosal closure or treatment of a full-thickness defect or perforation.

Physicians also need to consider the strengths and limitations of each device, device availability, compatibility with available endoscopes, and their own as well as the endoscopy staff’s familiarity and experience with the technique. Conventional through-the-scope clips remain the most utilized device because they are widely available and relatively easy to use, but larger or more complex defects may require tissue apposition clips, over-the-scope clips, endoscopic suturing, or a combination of techniques.

A major theme from the consensus was that we should think less in terms of identifying one universally superior device and more in terms of matching the closure strategy to the defect and the clinical situation.

Where do you see the greatest gaps in evidence for managing GI defects and perforations?

Dr. Hayat and Dr. Yang: The greatest gap is the lack of high-quality comparative studies that tell us which closure strategy works best for a particular type of defect. We have an expanding portfolio of devices, but much of the available evidence consists of observational studies, relatively small series, or studies evaluating individual technologies rather than head-to-head comparisons.

Perforation management is a particularly important area. In our Delphi process, not all the perforation-specific statements reached the predefined threshold for consensus. That likely reflects how heterogeneous perforations can be in their size, location, timing of recognition, tissue characteristics, and clinical circumstances. More prospective comparative data are needed to determine which devices or combinations of devices provide the most reliable and durable full-thickness closure in different settings.

There are also important unanswered questions regarding prophylactic closure, including which patients benefit most, the optimal approach for different GI locations, and the cost-effectiveness of newer closure technologies. Ultimately, we need studies that move beyond technical success and evaluate clinically meaningful outcomes such as delayed bleeding, perforation-related morbidity, need for surgery or hospitalization, durability of closure, and cost.